Search published articles


Showing 2 results for Power Distribution System

A. Fereidunian, H. Lesani, C. Lucas, M. Lehtonen, M. M. Nordman,
Volume 2, Issue 3 (7-2006)
Abstract

Almost all of electric utility companies are planning to improve their management automation system, in order to meet the changing requirements of new liberalized energy market and to benefit from the innovations in information and communication technology (ICT or IT). Architectural design of the utility management automation (UMA) systems for their IT-enabling requires proper selection of IT choices for UMA system, which leads to multi-criteria decision-makings (MCDM). In response to this need, this paper presents a model-based architectural design-decision methodology. The system design problem is formulated first then, the proposed design method is introduced, and implemented to one of the UMA functions–feeder reconfiguration function (FRF)– for a test distribution system. The results of the implementation are depicted, and comparatively discussed. The paper is concluded by going beyond the results and fair generalization of the discussed results finally, the future under-study or under-review works are declared.
Akanksha Jain, S.c. Gupta,
Volume 20, Issue 3 (9-2024)
Abstract

Due to the anticipated increase in loads, the power grid will encounter the issue of system peak loads in the future, which is typically addressed through grid reinforcement. However, implementing a flexibility service option can prevent the need for grid development. As the overall load continues to rise, the distribution transformer becomes overloaded. The presented work focuses on enhancing one of the parameters that define the insulation life of the transformer, known as the Loss-of-Life (LOL). Transactive approach involves the rescheduling of the battery and photovoltaic generation. Dominated Group Search Optimization (DGSO) algorithm is utilized to optimize the objective function of reducing the peak transformer load under the power flow and voltage constraints of the network. Experimental validation of the proposed method is conducted using MATLAB 2018 software. Modified IEEE 34-bus system is used to implement the proposed methodology. Numerical results obtained from various cases elucidate that the proposed model reduces the LOL of the transformer from 0.0103 to 0.0017 p.u.Comparative analysis of the proposed method with the already used methods of voltage-control and Volt-Var control have been presented.

Page 1 from 1     

Creative Commons License
© 2022 by the authors. Licensee IUST, Tehran, Iran. This is an open access journal distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) license.