Showing 3 results for Farshad
Moniri, Farshad,
Volume 2, Issue 1 (January 2006)
Abstract
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnostic test technique for transformers which could find mechanical as well as electrical faults such as detection and positioning of winding short circuit, winding movement, loss of clamping pressure, aging of insulation, etc. Yet there are several practical limitations to affect the accuracy and ease using this test as a regular condition monitoring technique in the field that many of them originated from noise and measuring errors. This paper purposes a transformer automated self diagnosis system can be installed on every power supply as a part of SCADA to extract FRA graphs from transformers and offers high repeatability which is a great benefit for FRA test. This is the first time that KALMAN Filter will be use in order to eliminate narrow-band and wide-band noises from FRA graphs that ends up not only smoothed measurement but also rate of changes that is so valuable in decision making and scheduling for transformers maintenance. So we will have an intelligent system which is able to predict the future of transformer using experience of not only own self but also all the transformers in an integrated network.
M. Farshad, J. Sadeh, H. Rajabi Mashhadi,
Volume 9, Issue 2 (June 2013)
Abstract
This paper presents a novel solution method for joint energy and Spinning Reserve (SR) dispatch problem. In systems in which the Lost Opportunity Cost (LOC) should be paid to generators, if the LOC is not considered in the dispatch problem, the results may differ from the truly optimum solution. Since the LOC is a non-differentiable function, including it in the formulation makes the problem solving process to be time-consuming and improper for real time applications. Here, the joint energy and SR dispatch problem considering the LOC in the objective function is reformulated as a Linear Programming (LP) problem which its solving process is computationally efficient. Also, with reliance on the performance of LP problem solving process, an iterative algorithm is proposed to overcome the self-referential difficulty arising from dependence of the LOC on the final solution. The IEEE 30-bus test system is used to examine the proposed solution method.
M. Farshad, J. Sadeh,
Volume 9, Issue 3 (September 2013)
Abstract
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is trained based on these normalized harmonic components. RF algorithm has the capability of learning patterns with a large number of features. The proposed approach only requires voltage signals measured at one-end hence, there are not problems of transmitting and synchronization of two-end data. In addition, current measurement is not required and the proposed approach is sheltered against current transformer errors and its saturation. No need for very high sampling frequency is another advantage of the proposed approach. Numerous tests carried out on a sample system indicate that accuracy of the proposed fault locator is secure against changing fault location, fault inception angle, fault resistance, and magnitude and direction of pre-fault load current. An average of 0.11% is obtained for the fault locating test errors.