Search published articles


Showing 4 results for Ardi

Sh. Mohammad-Nejad, M. Pourmahyabadi, A. Lajevardizadeh,
Volume 2, Issue 3 (October 2006)
Abstract

In this paper, the performance of a Ring Laser Gyro based inertial navigation is investigated. Dynamic and stochastic modeling are applied to gyro simulation and performance evaluation. In the dynamic model, some parameters such as scale factor and environmental sensitivity have been determined, whereas in the stochastic model, the other parameters such as random drift and measurement noise have been computed. The performance of the system is evaluated for several inputs. Also, the parameter variation of output noise as a result of changing the dither characteristics is analyzed.
A. Safari, H. Ardi,
Volume 14, Issue 1 (March 2018)
Abstract

In this paper, sliding mode control (SMC) for a bidirectional buck/boost DC-DC converter (BDC) with constant frequency in continuous conduction mode (CCM) is discussed. Since the converter is a high-order converter, the reduced-order sliding manifold is exploited. Because of right-half-plan zero (RHPZ) in the converter’s duty ratio to output voltage transfer function, sliding mode current controller is used. This controller benefits from various advantages such as fast dynamic response, robustness, stable and small variation of the settling time over a wide range of operation conditions. Because the converter operates in both step-down and step-up modes, two sliding manifold is derived for each mode. The existence and stability conditions are analyzed for both SMC in step-down and step-up modes. Finally, Simulation results are also provided to justify the feasibility of the controller using MATLAB/Simulink.

Pardis Asghari, Alireza Zakariazadeh,
Volume 19, Issue 4 (December 2023)
Abstract

This paper proposes a novel approach to analyzing and managing electricity consumption using a clustering algorithm and a high-accuracy classifier for smart meter data. The proposed method utilizes a multilayer perceptron neural network classifier optimized by an Imperialist Competitive Algorithm (ICA) called ICA-optimized MLP, and a CD Index based on Fuzzy c-means to optimally determine representative load curves. A case study involving a real dataset of residential smart meters is conducted to validate the effectiveness of the proposed method, and the results demonstrate that the ICA-optimized MLP method achieves an accuracy of 98.62%, outperforming other classification methods. This approach has the potential to improve energy efficiency and reduce costs in the power system, making it a promising solution for analyzing and managing electricity consumption.
Surya Hardi, Ferry R. A. Bukit, Irfan Nofri, Riza R. Wirasari, Muhd Hafizi Idris, Muzamir Isa,
Volume 21, Issue 2 (Special Issue on the 1st International Conference on ELECRiS 2024 Malaysia - June 2025)
Abstract

Overvoltage at the insulator terminal caused by a lightning strike can occur in two ways, i.e., a direct lightning strike on the phase line and ground wire. The insulator can be exposed to the phenomenon of back flashover (BFO) if the terminal voltage of the insulator is higher than its insulator critical voltage The lightning current characteristics are distinguished by the maximum current and the steepness. Differences in the characteristics in this study are identified as International Electrical Commission (IEC) and Conseil International des Grands Reseaux Electriques (CIGRE) impulse waveform standards. The footing-tower grounding system comes in different configurations, such as horizontal, vertical, and grid. Alternative transient program (ATP) software was used for simulating lightning strikes on ground wire and phase lines. The results exhibit that the highest critical voltage of the insulators on the footing tower through grid grounding when the surge current strikes ground wire (3308kV – 3395 kV), with the magnitude of the lightning current ranging from (48 kA – 3395 kA). For lightning direct stroke on the phase line, the critical voltage on vertical grounding is highest on (2938 kV -3021 kV).  The surge current flow footing-tower is highest on the grid. The currents magnitude flow in footing tower were influenced by impedance of grounding.

Page 1 from 1     