Abstract: (14191 Views)
This paper presents a parametric low differential order model, suitable for
mathematically analysis for Induction Machines with faulty stator. An adaptive Kalman
filter is proposed for recursively estimating the states and parameters of continuous–time
model with discrete measurements for fault detection ends. Typical motor faults as interturn
short circuit and increased winding resistance are taken into account. The models are
validated against winding function induction motor modeling which is well known in
machine modeling field. The validation shows very good agreement between proposed
method simulations and winding function method, for short-turn stator fault detection.
Type of Study:
Research Paper |
Received: 2008/10/07 | Accepted: 2013/12/30