Showing 7 results for Pal
S. Singh, M. D. Upadhayay, S. Pal,
Volume 17, Issue 2 (June 2021)
Abstract
In this manuscript, higher-order Orbital Angular Momentum (OAM) modes and parameters affecting vortex in the radiation pattern have been studied. A uniform circular array resonating at 10 GHz frequency is formed using eight identical rectangular patch antennas. Three uniform circular arrays are analyzed, simulated, and fabricated for OAM modes 0, +1, and -1 respectively. The higher-order OAM modes ±2, ±3, and ±4 are simulated and their effects on radiation and phase pattern are discussed. The effect of number of antenna elements and radius of the circular array on the phase purity of higher order OAM modes is presented. The results of simulated radiation patterns and phase front are well satisfying the generation of OAM modes. The measured results show a close agreement with the simulated result.
P. Paliwal,
Volume 18, Issue 1 (March 2022)
Abstract
The determination of a suitable technology combination for an isolated micro-grid (IMG) based on hybrid renewable energy resources (HRES) is a challenging task. The intermittent behavior of RES leads to an adverse impact on system reliability and thus complicates the planning process. This paper proposes a two-fold approach to provide a suitably designed HRES-IMG. Firstly, a reliability-constrained formulation based on load index of reliability (LIR) is developed with an objective to achieve a minimum levelized cost of energy (LCOE). Multi-state modeling of HRES-IMG is carried out based on hardware availability of generating units and uncertainties due to meteorological conditions. Modeling of battery storage units is realized using a multi-state probabilistic battery storage model. Secondly, an efficient optimization technique using a decentralized multi-agent-based approach is applied for obtaining high-quality solutions. The butterfly-PSO is embodied in a multi-agent (MA) framework. The enhanced version, MA-BFPSO is used to determine optimum sizing and technology combinations. Three different technology combinations have been investigated. The combination complying with LIR criterion and least LCOE is chosen as the optimal technology mix. The optimization is carried out using classic PSO, BF-PSO, and, MA-BFPSO and obtained results are compared. Further, in order to add a dimension in system planning, the effect of uncertainty in load demand has also been analyzed. The study is conducted for an HRES-IMG situated in Jaisalmer, India. The technology combination comprising of solar, wind, and battery storage yields the least LCOE of 0.2051 $/kWh with a very low value of LIR (0.08%). A reduction in generator size by 53.8% and LCOE by 16.5% is obtained with MABFPSO in comparison with classic PSO. The results evidently demonstrate that MA-BFPSO offers better solutions as compared to PSO and BF-PSO.
R. Gandotra, K. Pal,
Volume 18, Issue 3 (September 2022)
Abstract
The growing demand increases the maximum utilization of transmission and distribution lines which causes overloading, high losses, instability, contingency, and congestion. To enhance the performance of AC transmission and distribution systems FACTS devices are used. These devices assist in solving different issues of transmission lines such as instability, congestion, power flow, and power losses. Advancement in developed technology leads to the development of special application-based FACTS controllers. The main issues are concerned while placing the FACTS controller in the transmission and distribution lines to maximize the flow of power. Various methods like analytic method, arithmetic programming approaches, meta-heuristic optimization approaches, and hybrid approaches are being employed for the optimal location of FACTS controllers. This paper presents a review of various types of FACTS controllers available with both analytical and meta-heuristic optimization methods for the optimal placement of FACTS controllers. This paper also presents a review of various applications of FACTS devices such as stability improvement, power quality, and congestion management which are the main issues in smart power systems. Today’s smart power systems comprise the smart grids with smart meters and ensure continuous high quality of power to the consumers.
P. Paliwal,
Volume 18, Issue 4 (December 2022)
Abstract
This paper presents a multi-stage planning framework for analysis of stochastic distributed energy resources (DERs) comprising of solar, wind, and battery storage. The existing models do not consider penetration level analysis in conjunction with sizing, placement, and economic assessment. The main objective of this research is to embed all these dimensions of system planning in one structure. The first stage involves reliability constrained component sizing. The second stage pertains to placement of DERs based on loss minimization and voltage profile. The third stage is the main thrust of this work which provides exhaustive economic evaluation and cost-benefit analysis. The novelty of this work lies in the consideration of penetration level in backdrop of all three stages. The proposed formulation is implemented on a 33-Bus radial distribution feeder located in Jaisalmer, Rajasthan, India. Four penetration levels viz. 10, 20, 40, and 60 percent have been investigated and analyzed under different planning scenarios. The results facilitate the determination of optimum penetration level.
N. Thakkar, P. Paliwal,
Volume 18, Issue 4 (December 2022)
Abstract
In the last decade, there has been a lot of focus on sustainable development in the electrical power industry to meet the growing energy demand. This has led to an increase in the integration of renewable energy sources (RES). In addition to being abundantly available, the RES offers advantages such as low environmental impact and increased social development of rural communities which are imperative for a sustainable society. However, the selection of a particular generating resource or resource mix (RM) for an autonomous micro-grid is a complex problem that involves multiple conflicting factors. In this paper, a planning strategy for selecting an appropriate RM has been proposed. Seven RMs comprising different combinations of four generation/storage technologies such as solar photovoltaic array (SPVA), wind turbine (WT), diesel generator (DG) and battery storage (BS) have been considered. The planning is initiated with the determination of optimal component sizing for all seven RMs. The RMs are then analyzed with respect to four primary sustainability parameters i.e. economic, social, technical and environmental. The analysis is further enhanced by investigation of 13 sub-parameters as well. Thereafter, prioritization of RMs is carried out using two MCDM methods: Best worst method (BWM) and PROMETHEE II. Finally, to assert the importance of weight assignment on RM ranking, sensitivity analysis is performed. In order to impart the practical aspect to analysis, the planning formulation is applied to a case study of the Thar desert, India. The results suggest that a combination of SPVA and BS provides the most optimum RM solution.
Ananthakrishna T, Guru Prasad, A. Gopalkrishna Pai ,
Volume 19, Issue 3 (September 2023)
Abstract
This paper presents a low dropout voltage regulator, with the specifications suitable for hearing aid devices. The proposed LDO occupies very less area on chip and provides an excellent transient response. A novel voltage spike suppressor block is employed in the LDO architecture which reduces undershoot and overshoot of the output voltage during the abrupt load transition. It introduces a secondary negative feedback loop whose delay is lesser than the main loop and also steers the quiescent current to output node when required. This not only improves overall current efficiency but also reduces the on chip capacitance. The proposed LDO is laid out in 180 nm standard CMOS technology and post layout simulations are carried out. The LDO produces 0.9 V output when a minimum supply voltage of 1 V is applied. A maximum load of 0.5 mA can be driven by the regulator. The LDO exhibits 4.4 mV/V and 800 μV/mA line and load regulations respectively. When subjected to a step load change, an undershoot of 20.34 mV and an overshoot of 30.28 mV are recorded. For proper operation of the LDO, it requires only 4.5 pF on-chip capacitance.
Srinivas Babu N, Shashikiran S, M Jayanthi, Rajani N, K M Palaniswamy, M R Kushalatha,
Volume 20, Issue 0 (In Press 2024)
Abstract
Tuberculosis (TB) is a dangerous disease caused by mycobacterium leads to mortality. Early detection and identification of tuberculosis is crucial for managing tuberculosis infections. Recent technological improvements use a machine learning-based SVM and Modified CNN to identify specific diseases more accurately, as demonstrated in this research. The modified CNN's improved feature extraction and classification accuracy are maintained throughout construction. To obtain good performance a TBX11K publicly accessible dataset is used it consists of 11000 images of which 4600 chest x-ray (CXR) images are considered in this research, and the suggested model is verified. This approach significantly increases the accuracy of categorizing TB symptoms. The PCA in this system locates the elements and extracts a large amount of variance technique applied to the full chest radiograph for pulmonary tuberculosis identification accuracy using SVM is 93.14% and modified CNN 96.72% respectively. When it comes to helping radiologists diagnose patients and public health professionals screen for tuberculosis in places where the disease is endemic, the proposed system SVM and modified CNN perform better than existing methods.