Showing 4 results for Damchi
Y Damchi, J Sadeh,
Volume 9, Issue 4 (December 2013)
Abstract
Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI) plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.
Y. Damchi, J. Sadeh, H. Rajabi Mashhadi,
Volume 11, Issue 2 (June 2015)
Abstract
The aim of the relay coordination is that protection systems detect and isolate the faulted part as fast and selective as possible. On the other hand, in order to reduce the fault clearing time, distance protection relays are usually equipped with pilot protection schemes. Such schemes can be considered in the distance and directional overcurrent relays (D&DOCRs) coordination to achieve faster protection systems, while the selectivity is maintained. Therefore, in this paper, a new formulation is presented for the relay coordination problem considering pilot protection. In the proposed formulation, the selectivity constraints for the primary distance and backup overcurrent relays are defined based on the fault at the end of the transmission lines, rather than those at the end of the first zone of the primary distance relay. To solve this nonlinear optimization problem, a combination of genetic algorithm (GA) and linear programming (LP) is used as a hybrid genetic algorithm (HGA). The proposed approach is tested on an 8-bus and the IEEE 14-bus test systems. Simulation results indicate that considering the pilot protection in the D&DOCRS coordination, not only obtains feasible and effective solutions for the relay settings, but also reduces the overall operating time of the protection system.
Y. Damchi, J. Sadeh, H. Rajabi Mashhadi,
Volume 11, Issue 3 (September 2015)
Abstract
Most studies in relay coordination have focused solely on coordination of overcurrent relays while distance relays are used as the main protection of transmission lines. Since, simultaneous coordination of these two types of relays can provide a better protection, in this paper, a new approach is proposed for simultaneous coordination of distance and directional overcurrent relays (D&DOCRs). Also, pursued by most of the previously published studies, the settings of D&DOCRs are usually determined based on a main network topology which may result in mis-coordination of relays when changes occur in the network topology. In the proposed method, in order to have a robust coordination, network topology changes are taken into account in the coordination problem. In the new formulation, coordination constraints for different network topologies are added to those of the main topology. A complex nonlinear optimization problem is derived to find the desirable relay settings. Then, the problem is solved using hybridized genetic algorithm (GA) with linear programming (LP) method (HGA). The proposed method is evaluated using the IEEE 14-bus test system. According to the results, a feasible and robust solution is obtained for D&DOCRs coordination while all constraints, which are due to different network topologies, are satisfied.

A. Mirsamadi, Y. Damchi, M. Assili,
Volume 17, Issue 1 (March 2021)
Abstract
Power systems should have acceptable reliability in order to operate properly. Highly available and dependable protective relays help to obtain the desirable reliability. The relays should be periodically evaluated during specific intervals to achieve the mentioned characteristics. The Routine Test Interval (RTI) should be optimized in order to economically maximize the reliability of the protection system. The failure rate of the relays plays a vital role in determination of the Optimum Routine Test Interval (ORTI). Human error is one of the effective factors in the failure rate of the relays. Therefore, in this paper, a Markov model is proposed to investigate the impact of human error on the failure rate and the ORTI of the protection system. The model is applied for the protection system of power transformer. The obtained results indicated that human error has a significant impact on the increase of protection system failure, the decrease of the desired reliability indices, and the reduction of ORTI of the protection system.