Search published articles


Showing 2 results for Signal Matching Analysis

Shahram Feizee Masouleh, Kazem Fakharian,
Volume 6, Issue 3 (9-2008)
Abstract

A finite-difference based continuum numerical model is developed for the pile-soil dynamic response during pile driving. The model is capable of simulating the wave propagation analysis along the pile shaft and through the soil media. The pile-soil media, loading and boundary conditions are such that axisymmetric assumption seems to be an optimized choice to substantially reduce the analysis time and effort. The hydrostatic effect of water is also considered on the effective stresses throughout the soil media and at the pilesoil interface. The developed model is used for signal matching analysis of a well-documented driven pile. The results showed very good agreement with field measurements. It is found that the effect of radiation damping significantly changes the pile-soil stiffness due to the hammer blow. The pile tip response shows substantial increase in soil stiffness below and around the pile tip due to driving efforts.
I. Hosseinzadeh Attar, K. Fakharian,
Volume 11, Issue 2 (11-2013)
Abstract

Pile foundations are frequently used in industrial projects in southwest lowlands of Iran. Although high setup of shaft resistance

is usually reported in the area, no reliable formulation or guidelines are available for considering the increased capacity in design

applications. Therefore, the pile design practices are usually not optimized. The main objective of this paper is presenting a site

specific formulation for setup effects of a utility plant in southwest Iran in which a good database of prestressed concrete driven

piles is available. Fajr-II Petrochemical site in PetZone of Mahshahr accommodating a utility plant is selected as the database of

the current study. The setup factor (A) and the reference time (t0) are evaluated through processing of a relatively large database

of this well-supervised piling project. As the main portion of variations of driven piles capacity with time is related to shaft, only

shaft resistance variations are considered in this research. The shaft capacity variations are derived from signal matching analysis

on PDA tests. Reliability of PDA tests has been confirmed through comparing with the static load test results. Influence of driving

the surrounding piles on setup factor is also investigated. The results show that the average setup factor (A) and the reference time

(t0) of 0.30 and 0.01 day, respectively, are proper values for estimating the long term capacity in this region. Evaluation of the

results indicates that driving 8 piles around the test pile has increased the “A” factor average of 40% resultingin increase of the

shaft capacity about 19% in one month and 22% in one year, in comparison with the tested piles with no surrounding piles driven.



Page 1 from 1     

© 2024 CC BY-NC 4.0 | International Journal of Civil Engineering

Designed & Developed by : Yektaweb