F. R. Rofooei, N. K. Attari, A. Rasekh, A.h. Shodja,
Volume 4, Issue 3 (9-2006)
Abstract

Pushover analysis is a simplified nonlinear analysis technique that can be used to estimate the dynamic demands imposed on a structure under earthquake excitations. One of the first steps taken in this approximate solution is to assess the maximum roof displacement, known as target displacement, using the base shear versus roof displacement diagram. That could be done by the so-called dynamic pushover analysis, i.e. a dynamic time history analysis of an equivalent single degree of freedom model of the original system, as well as other available approximate static methods. In this paper, a number of load patterns, including a new approach, are considered to construct the related pushover curves. In a so-called dynamic pushover analysis, the bi-linear and tri-linear approximations of these pushover curves were used to assess the target displacements by performing dynamic nonlinear time history analyses. The results obtained for five different special moment resisting steel frames, using five earthquake records were compared with those resulted from the time history analysis of the original system. It is shown that the dynamic pushover analysis approach, specially, with the tri-linear approximation of the pushover curves, proves to have a better accuracy in assessing the target displacements. On the other hand, when nonlinear static procedure seems adequate, no specific preference is observed in using more complicated static procedures (proposed by codes) compared to the simple first mode target displacement assessment.
Mehdi Poursha, Faramarz Khoshnoudian, Abdoreza S. Moghadam,
Volume 6, Issue 2 (6-2008)
Abstract

The nonlinear static pushover analysis technique is mostly used in the performance-based design of structures and it is favored over nonlinear response history analysis. However, the pushover analysis with FEMA load distributions losses its accuracy in estimating seismic responses of long period structures when higher mode effects are important. Some procedures have been offered to consider this effect. FEMA and Modal pushover analysis (MPA) are addressed in the current study and compared with inelastic response history analysis. These procedures are applied to medium high-rise (10 and 15 storey) and high-rise (20 and 30 storey) frames efficiency and limitations of them are elaborated. MPA procedure present significant advantage over FEMA load distributions in predicting storey drifts, but the both are thoroughly unsuccessful to predict hinge plastic rotations with acceptable accuracy. It is demonstrated that the seismic demands determined with MPA procedure will be unsatisfactory in nonlinear systems subjected to individual ground motions which inelastic SDF systems related to significant modes of the buildings respond beyond the elastic limit. Therefore, it’s inevitable to avoid evaluating seismic demands of the buildings based on individual ground motion with MPA procedure.
F.r. Rofooei, M. R. Mirjalili, N. K. A. Attari,
Volume 10, Issue 4 (12-2012)
Abstract

The nonlinear static procedures (NSPs) proposed by design codes do not lead to reliable results especially for tall buildings.

They generally provide inconsistent estimates of inelastic seismic demands, especially for the top floors due to their inabilities in

considering the higher modes effects. In this paper, a new enhanced pushover procedure is proposed which is based on the

envelope of the structural responses resulting from two separate pushover analyses as a combination rule. Also, the suggested

pushover analyses are performed using a newly proposed modal load pattern, i.e., the Modal Spectra Combination (MSC), and

the ASCE41-06 required first mode load pattern. The MSC load pattern is consisted of a number of mode shapes combined with

appropriate weighting factors that depend on their modal participation factors, modal frequencies and design spectral values. A

number of 2-D steel moment resisting frame models with different number of stories are used to investigate the efficiency of the

proposed method. The inter-story drifts and the maximum plastic beam moment and curvature responses are used as a measure

to compare the results obtained from the nonlinear time-history analyses (NL-THA) and some other NSPs. The results obtained

through rigorous nonlinear dynamic analyses show that the application of the proposed method leads to acceptable results for

steel MRF systems in comparison to other available enhanced NSPs. The OpenSees program is used for numerical analysis.


M. Poursha,
Volume 11, Issue 2 (6-2013)
Abstract

Double- unsymmetric-plan medium-rise buildings subjected to bi-directional seismic excitation are complex structures where higher-mode effects in plan and elevation are important in estimating the seismic responses using nonlinear static or pushover analysis. Considering two horizontal components of the ground motions makes the problem more intricate. This paper presents a method for nonlinear static analysis of double unsymmetric-plan low- and medium-rise buildings subjected to the two horizontal components of ground motions. To consider bi-directional seismic excitation in pushover analyses, the proposed method utilizes an iterative process until displacements at a control node (centre of mass at the roof level) progressively reach the predefined target displacements in both horizontal directions. In the case of medium-rise buildings, continuous implementation of modal pushover analyses is used to take higher-mode effects into account. To illustrate the applicability and to appraise the accuracy of the proposed method, it is applied to the 4- and 10-storey torsionally-stiff and torsionally-flexible buildings as representative of low- and medium-rise buildings, respectively. For the purpose of comparison, modal pushover analysis (MPA) is also implemented considering the two horizontal components of the ground motions. The results indicate that the proposed method and the MPA procedure can compute the seismic demands of double unsymmetric-plan low- and medium-rise buildings with reasonable accuracy however, seismic responses resulting from the proposed method deteriorate at the flexible edge of the torsionally-flexible buildings
E. Wahyuni, Y. Tethool,
Volume 13, Issue 2 (6-2015)
Abstract

The purpose of this study is to determine the effect of vierendeel panel width and vertical truss spacing ratio in an inelastic behavior of the STF system due to earthquake loads. The STF system is applied to a six-storey building that serves as apartments [2]. The STF system is used in the building in the transverse direction (N-S direction), while in the longitudinal direction (W-E direction) the building system uses the special moment resisting frame. The structural behavior was evaluated using nonlinear pushover and time history analyses. The results showed that by increasing the ratio of vierendeel panel width and vertical truss spacing, the ductility of the structure was increased. Based on the performance evaluation, the ratio of the vierendeel panel width and vertical truss spacing on the STF buildings that provided satisfactory performance was more or equal to 1.6. The ultimate drift obtained from non-linear time history analysis was smaller than the pushover analysis. This result showed that the static nonlinear pushover analysis was quite conservative in predicting the behavior of the six-storey building in an inelastic condition.
Dr. Abazar Asghari, Mr. Behnam Azimi Zarnagh,
Volume 15, Issue 5 (7-2017)
Abstract

For years, coupling shear walls have been used in  the mid to high-rise buildings as a part of lateral load- resisting system mostly, because of their ability to control the displacement of structures, Recently by changing the design codes from strength based design to performance based  design, nonlinear behavior of coupled walls became important for practical engineers, so that many researchers  are looking for ways to improve and also predict the behavior of coupled walls under severe earthquakes. This paper  presents  the results of   linear,  nonlinear static ( pushover)  and  nonlinear inelastic time-history analysis  of a 10-story  two- dimensional coupling shear wall (CSW) which is perforated with 3 different patterns which are taken from considering  the S22 stress of shell elements used for modeling shear walls,  nonlinear static analysis results confirm that perforation can increase the response modification  factor of coupled walls up to 33 percent and also the results of  linear analysis and design indicate that perforation can reduce the amount of reinforcement of coupling beams and other frame's  structural components. Also results of nonlinear inelastic time history  analysis confirm that by using perforation patterns the base shear- roof displacement hysteretic response get better and the  systems with perforation patterns can absorb more energy under severe earthquakes.