Search published articles


Showing 5 results for Performance-Based Design

Ghodrati Amiri G., Sedighi S.,
Volume 2, Issue 4 (12-2004)
Abstract

In the past decade design procedure changed to �performance-based design� from�force-based design�, by this mean many researchers focused on nonlinear static analysis (NSA)and the procedure named �PUSHOVER�. Advantages of this method are defining the inelasticbehavior of structure without nonlinear dynamic analysis (NDA) effort and also defining plastichinges formation in critical elements, and the order of formed plastic hinges. In spite of these goodadvantages NSA is limited to short and planar structures and application of that in tall andtorsionaly asymmetric structures may yield unreliable results.In this study reliability of NSA is investigated by performing both nonlinear static and dynamicanalysis on six 2D moment resisting concrete frames. Non linear dynamic analysis has been doneby the suggested method in FEMA356 guideline called �Target Displacement Method�. A groupof 4 different lateral increasing loads were used in pushover analysis and 3 different groundmotions were applied in NDA. Results indicate that same responses can be obtained by performingNSA, but errors will be increased by frames height increment.
Mehdi Poursha, Faramarz Khoshnoudian, Abdoreza S. Moghadam,
Volume 6, Issue 2 (6-2008)
Abstract

The nonlinear static pushover analysis technique is mostly used in the performance-based design of structures and it is favored over nonlinear response history analysis. However, the pushover analysis with FEMA load distributions losses its accuracy in estimating seismic responses of long period structures when higher mode effects are important. Some procedures have been offered to consider this effect. FEMA and Modal pushover analysis (MPA) are addressed in the current study and compared with inelastic response history analysis. These procedures are applied to medium high-rise (10 and 15 storey) and high-rise (20 and 30 storey) frames efficiency and limitations of them are elaborated. MPA procedure present significant advantage over FEMA load distributions in predicting storey drifts, but the both are thoroughly unsuccessful to predict hinge plastic rotations with acceptable accuracy. It is demonstrated that the seismic demands determined with MPA procedure will be unsatisfactory in nonlinear systems subjected to individual ground motions which inelastic SDF systems related to significant modes of the buildings respond beyond the elastic limit. Therefore, it’s inevitable to avoid evaluating seismic demands of the buildings based on individual ground motion with MPA procedure.
H. Shakib, Gh. R. Atefatdoost,
Volume 12, Issue 1 (3-2014)
Abstract

An approach was formulated for the nonlinear analysis of three-dimensional dynamic soil-structure interaction (SSI) of asymmetric buildings in time domain in order to evaluate the seismic response behavior of torsionally coupled wall-type buildings. The asymmetric building was idealized as a single-storey three-dimensional system resting on different soil conditions. The soil beneath the superstructure was modeled as nonlinear solid element. As the stiffness of the reinforced concrete flexural wall is a strength dependent parameter, a method for strength distribution among the lateral force resisting elements was considered. The response of soil-structure interaction of the system under the lateral component of El Centro 1940 earthquake record was evaluated and the effect of base flexibility on the response behavior of the system was verified. The results indicated that the base flexibility decreased the torsional response of asymmetric building so that this effect for soft soil was maximum. On the other hand, the torsional effects can be minimized by using a strength distribution, when the centre of both strength CV and rigidity CR is located on the opposite side of the centre of mass CM, and SSI has no effect on this criterion.
Guray Arslan, Muzaffer Borekci, Muzaffer Balci, Melih Hacisalihoglu,
Volume 14, Issue 3 (4-2016)
Abstract

The contribution of concrete to inelastic deformation capacity and shear strength of reinforced concrete (RC) columns failing in shear has been investigated extensively by various researchers. Although RC members are designed to have shear strengths much greater than their flexural strengths to ensure flexural failure according to the current codes, shear degradation of RC columns failing in flexure has not been studied widely. The aim of this study is to investigate the shear degradation of RC columns using finite element analyses (FEA). The results of FEA are compared with the results of experimental studies selected from literature, and it is observed that the lateral load-deflection curves of analysed columns are compatible with the experimental results. Twenty-six RC columns were analysed under monotonically increasing loads to determine the concrete contribution to shear strength. The results of analyses indicate that increasing the ratio of shear to flexural strength reduces the concrete contribution to shear strength of the columns.


Behrouz Behnam,
Volume 14, Issue 8 (12-2016)
Abstract

Observations and investigations have proved that using traditional fire curves such as stand-ard fire curves and natural fire curves should be limited to small/medium compartments. In addition, when using the traditional fire curves, a uniform temperature is assumed throughout the compartment. However, for large open compartments, assuming uniform temperature is not compatible with real fires. To overcome this limitation, a non-uniform fire method named as travelling fire is employed as an alternative. A study is performed here on a seismic-damaged large plan 3-story reinforced concrete structure designed to meet the life safety level of performance when exposed to a travelling fire. To draw a comparison, the structural fire analysis is also performed using the traditional methods. The results show a notable difference – while the fire resistance based on the travelling fire is around 91 minutes, it is around 140 minutes when based on a uniform temperature. This shows that the structure studied is more susceptible to failure when subjected to the non-uniform fire than the uniform fire.



Page 1 from 1     

© 2019 All Rights Reserved | International Journal of Civil Engineering

Designed & Developed by : Yektaweb