M. Biglari, I. Ashayeri,
Volume 11, Issue 2 (11-2013)
Abstract

Seismic ground motion is profoundly affected by geometrical and mechanical properties of soil deposits overlaying bedrock.

Local seismic ground response of saturated soil deposits was studied in literature by applying the effects of soil stress state

and index properties on the strain-dependent normalized shear modulus reduction, G/G0, and damping ratio, D, curves in an

equivalent linear analysis. However, experimental investigations revealed that, G0, G/G0, and D of unsaturated soils are

influenced by stress state as well as suction. This study presents the results of linear and equivalent linear seismic ground response

analysis of unsaturated soil deposits incorporating suction effects on G/G0 and D curves. Seismic ground response analyses were

done with the computer program EERA for three sets of soil profiles, which are included in saturated, constant and linearly

variable suction unsaturated soil deposits. The results of current study present the magnitude of variation in natural frequency,

amplification ratio and spectral acceleration of unsaturated soil deposits.


H. Shakib, Gh. R. Atefatdoost,
Volume 12, Issue 1 (3-2014)
Abstract

An approach was formulated for the nonlinear analysis of three-dimensional dynamic soil-structure interaction (SSI) of asymmetric buildings in time domain in order to evaluate the seismic response behavior of torsionally coupled wall-type buildings. The asymmetric building was idealized as a single-storey three-dimensional system resting on different soil conditions. The soil beneath the superstructure was modeled as nonlinear solid element. As the stiffness of the reinforced concrete flexural wall is a strength dependent parameter, a method for strength distribution among the lateral force resisting elements was considered. The response of soil-structure interaction of the system under the lateral component of El Centro 1940 earthquake record was evaluated and the effect of base flexibility on the response behavior of the system was verified. The results indicated that the base flexibility decreased the torsional response of asymmetric building so that this effect for soft soil was maximum. On the other hand, the torsional effects can be minimized by using a strength distribution, when the centre of both strength CV and rigidity CR is located on the opposite side of the centre of mass CM, and SSI has no effect on this criterion.
M. Afzalirad, M. Kamalian, M. K. Jafari, A. Sohrabi-Bidar,
Volume 12, Issue 1 (1-2014)
Abstract

In this paper, an advanced formulation of time-domain, two-dimensional Boundary Element Method (BEM) with material damping is presented. Full space two-dimensional visco-elastodynamic time-convoluted kernels are proposed in order to incorporate proportional damping. This approach is applied to carry out site response analysis of viscoelastic topographic structures subjected to SV and P incident waves. Seismic responses of horizontally layered site, semi-circular canyons, slope topography and ridge sections subjected to these incident waves are analyzed in order to demonstrate the accuracy of the kernels and the applicability of the presented viscoelastic boundary element algorithm. The results show an excellent agreement with recent published results obtained in frequency domain. Also, the effects of different material damping ratios on site response are investigated.
M. B. Esfandiari Sowmehsaraei, R. Jamshidi Chenari,
Volume 12, Issue 1 (1-2014)
Abstract

Soil reinforced with fiber shows characteristics of a composite material, in which fiber inclusion has a significant effect on soil permeability. Concerning to the higher void ratio of carpet fibers, at first stages it may be expected that an increase in fiber content of the reinforced soil would result in an increase in permeability of the mixture. However, the present article demonstrates that fiber inclusion will decrease the permeability of sand-fiber composite.A series of constant head permeability tests have been carried out to show the effects and consequently, a new system of phase relationships was introduced to calculate the dry mass for the sand portion of the composite. Monte Carlo simulation technique adopted with finite element theory was employed to back calculate the hydraulic conductivity of individual porous fibers from the laboratory test results. It was observed that the permeability coefficient of the porous fibers are orders of magnitude less than the skeletal sand portion due to the fine sand particle entrapment and also the fiber volume change characteristics.
C. Vieira,
Volume 12, Issue 1 (1-2014)
Abstract

This paper presents a simplified approach to estimate the resultant force, which should be provided by a retention system, for the equilibrium of unstable slopes. The results were obtained with a developed algorithm, based on limit equilibrium analyses, that assumes a two-part wedge failure mechanism. Design charts to obtain equivalent earth pressure coefficients are presented. Based on the results achieved with the developed computer code, an approximate equation to estimate the equivalent earth pressure coefficients is proposed. Given the slope angle, the backslope, the design friction angle, the height of the slope and the unit weight of the backfill, one can determine the resultant force for slope equilibrium. This simplified approach intends to provide an extension of the Coulomb earth pressure theory to the stability analyses of steep slopes and to broaden the available design charts for steep reinforced slopes with non-horizontal backslopes
O. Farzaneh, F. Askari, J. Fatemi,
Volume 12, Issue 4 (12-2014)
Abstract

AWT IMAGEPresented is a method of two-dimensional analysis of the active earth pressure due to simultaneous effect of both soil weight and surcharge of strip foundation. The study’s aim is to provide a rigorous solution to the problem in the framework of upper-bound theorem of limit analysis method in order to produce some design charts for calculating the lateral active earth pressure of backfill when loaded by a strip foundation. A kinematically admissible collapse mechanism consisting of several rigid blocks with translational movement is considered in which energy dissipation takes place along planar velocity discontinuities. Comparing the lateral earth forces given by the present analysis with those of other researchers, it is shown that the results of present analysis are higher (better) than other researchers’ results. It was found that with the increase in AWT IMAGE, the proportion of the strip load (q) which is transmitted to the wall decreases. Moreover, Increasing the friction between soil and wall ( AWT IMAGE) will result in the increase of effective distance ( AWT IMAGE). Finally, these results are presented in the form of dimensionless design charts relating the mechanical characteristics of the soil, strip load conditions and active earth pressure.