M.h. Baziar, Sh. Salemi, T. Heidari,
Volume 4, Issue 3 (9-2006)
Abstract

Seismic behavior of a rockfill dam with asphalt-concrete core has been studied utilizing numerical models with material parameters determined by laboratory tests. The case study selected for these analyses, is the Meyjaran asphalt core dam, recently constructed in Northern Iran, with 60 m height and 180 m crest length. The numerical analyses have been performed using a nonlinear three dimensional finite difference software and various hazard levels of earthquakes. This study shows that due to the elasto-plastic characteristics of the asphalt concrete, rockfill dams with asphalt concrete core behave satisfactorily during earthquake loading. The induced shear strains in the asphalt core, for the case presented in this research, are less than 1% during an earthquake with amax=0.25g and the asphalt core remains watertight. Due to large shear deformations caused by a more severe earthquake with amax=0.60g, some cracking may occur towards the top of the core (down to 5-6 m), and the core permeability may increase in the top part, but the dam is safe.
M. Heidarzadeh, A.a. Mirghasemi, S. Etemadzadeh,
Volume 5, Issue 1 (3-2007)
Abstract

A new chemical grouting method has been developed for conglomerate formations based on the experimental studies. Due to the lack of chemical grouting experience of conglomerate formations, the testing programs were performed to evaluate the performance of chemical grouting in the water sealing of part of conglomerate foundation of Karkheh earth dam using a combination of field and laboratory tests. First, the chemical grouts alone were examined with regard to viscosity-time behavior, gelation time, temperature-influence, stability, and deformability. These laboratory tests, led to the selection of the final chemical grout which was a solution of sodium silicate, water, and ethyl acetate as reactant. The second step tested grout-soil interaction: The injectability and permeability reduction of the selected chemical grout was examined in field injection tests. In this step two field tests were performed including shallow test holes without hydrostatic pressure and full scale tests under dam real hydrostatic pressure head. Based on these two field injection tests, performed in the conglomerate foundation of Karkheh dam, a new chemical grouting method for conglomerate formations is proposed and satisfactory results led to the recommendation of this method for eventually successful application.
S.n. Moghaddas Tafreshi, Gh. Tavakoli Mehrjardi, S.m. Moghaddas Tafreshi,
Volume 5, Issue 2 (6-2007)
Abstract

The safety of buried pipes under repeated load has been a challenging task in geotechnical engineering. In this paper artificial neural network and regression model for predicting the vertical deformation of high-density polyethylene (HDPE), small diameter flexible pipes buried in reinforced trenches, which were subjected to repeated loadings to simulate the heavy vehicle loads, are proposed. The experimental data from tests show that the vertical diametric strain (VDS) of pipe embedded in reinforced sand depends on relative density of sand, number of reinforced layers and height of embedment depth of pipe significantly. Therefore in this investigation, the value of VDS is related to above pointed parameters. A database of 72 experiments from laboratory tests were utilized to train, validate and test the developed neural network and regression model. The results show that the predicted of the vertical diametric strain (VDS) using the trained neural network and regression model are in good agreement with the experimental results but the predictions obtained from the neural network are better than regression model as the maximum percentage of error for training data is less than 1.56% and 27.4%, for neural network and regression model, respectively. Also the additional set of 24 data was used for validation of the model as 90% of predicted results have less than 7% and 21.5% error for neural network and regression model, respectively. A parametric study has been conducted using the trained neural network to study the important parameters on the vertical diametric strain.
S.m. Mir Mohammad Hosseini, A.a. Hajimohammadi, A. R. Hajimohammadi,
Volume 8, Issue 2 (6-2010)
Abstract

Seismic piezocone device (SCPTu) together with Resonant Column and Cyclic Triaxial test apparatus are

employed to measure small strain shear modulus (G0) of carbonate sandy and clayey soils of southern coasts of Iran.

A large area of southern regions of Iran is formed from clay, silt and sand. In this study, maximum shear modulus that

is derived from both field (by seismic piezocone) and laboratory (by Resonant Column and Cyclic Triaxial) tests on

soil samples from the southern region, indicated a meaningful effect of sample disturbance. Results show that in

laboratory tests, loose samples tend to become denser and therefore exhibit greater stiffness whereas dense samples

tend to become looser, showing a reduction in stiffness. According to the results of the present study, there are narrow

limits of soils shear moduli for which the laboratory tests and the field measurements yield approximately the same

amounts. This limit of shear moduli is about 30-50(MPa) for clay deposits and 70-100 (MPa) for sandy deposits. Since

the shear moduli of soils in small strains can also be computed from the shear wave velocity, also correlations based

on parameters derived from SCPTu test for shear wave velocity determination of sandy and clayey soils of the studied

area are presented. This study shows that shear wave velocity can be related to both corrected tip resistance and total

normal stress. The measurements of the damping ratio and shear module, because of a great disturbance of stiff

deposits during the sampling process and also due to considerable differences between the laboratory and field

results, by the laboratory approaches are not reliable and advised.


Mahmoud Reza Abdi,
Volume 9, Issue 2 (6-2011)
Abstract

The use of various slags as by-products of steel industry is well established in civil engineering applications. However, the use

of BOS slag in the area of soil stabilization has not been fully researched and developed despite having similar chemical

composition and mineralogy to that of Portland cement. This paper reports on efforts to extend the use of BOS slag to soil

stabilization by determining possible beneficial effects it may have on compressive strength and durability. Results of laboratory

tests conducted on kaolinite samples stabilized with lime and treated with various percentages of BOS slag are presented. Tests

determined strength development of compacted cylinders, moist cured in a humid environment at 35° C and durability by freezing

and thawing method. Results showed that additions of BOS slag to kaolinite samples singularly or in combination with lime

increased unconfined compressive strength and durability. These characteristics were significantly enhanced by the concurrent

use of lime and BOS slag for stabilization of kaolinite.


Nader Shariatmadari , Marzieh Salami, Mehran Karimpour Fard,
Volume 9, Issue 2 (6-2011)
Abstract

The main task in the design and construction of impermeable liners in landfills is to block the migration of pollutants to the groundwater

systems or to reduce its rate to a reasonable amount. That is why environmental regulations force governments to construct engineered

waste dumps for waste management purposes. These liners are exposed to various types of chemical, biological, and physical processes

and are affected by the leachate which is produced from decomposition of waste materials accompanying methane gas. The leachate

includes a lot of components such as water and different types of salts. For this reason, the geotechnical characteristics of clay liners

which are evaluated in laboratories using distilled water or tap water might be far different from the representative sample of the in-situ

conditions. There are some evidences regarding the effect of these salts on the physical and mechanical properties of clay barriers which

could affect the long-term performance of these liners. Since the main criterion for impermeable bottom liners in landfills is their

hydraulics conductivity, the increase of this parameter could have a considerable environmental impact. This paper embraces the results

of a recent study on the effect of three inorganic salts, NaCl, CaCl2 and MgCl2 on some geotechnical properties of a common used clay

soil in impermeable bottom barrier in Kahrizak landfill, the main waste disposal center of the Tehran Metropolitan. Also the effect of

bentonite content by adding different percentage of this special clay mineral, 10 and 20 percent, on these properties was investigated.

Laboratory tests like liquid limit, compaction, 1D consolidation and free swell tests were performed for this purpose. Results indicated

that all of these salts could have a considerable effect on the geotechnical properties of the mixtures. The main reason of such effects is

the changes which occur in diffuse double layer of clay particles.


R. Mahin Roosta, A. Alizadeh,
Volume 10, Issue 2 (6-2012)
Abstract

In the first impounding of rockfill dams, additional settlements occur in upstream side in saturated rockfills due to collapse
phenomenon even high rainy seasons can cause additional deformation in the dumped rockfills. Unfortunately these
displacements are not taken into account in the conventional numerical models which are currently used to predict embankment
dam behavior during impounding. In this paper to estimate these displacements, strain hardening-strain softening model in Flac
is modified based on the laboratory tests, in which same impounding process in such dams is considered. Main feature of the
model is reproduction of nonlinear behavior of rockfill material via mobilized shear strength parameters and using collapse
coefficient to display induced settlement due to inundation. This mobilization of shear strength parameters associated with some
functions for dilatancy behavior of rockfill are used in a finite difference code for both dry and wet condition of material. Collapse
coefficient is defined as a stress dependent function to show stress release in the material owing to saturation. To demonstrate
how the model works, simulation of some large scale triaxial tests of rockfill material in Gotvand embankment dam is presented
and results are compared with those from laboratory tests, which are in good agreement. The technique could be used with any
suitable constitutive law in other coarse-grained material to identify collapse settlements due to saturation


J. Nazari Afshar, M. Ghazavi,
Volume 12, Issue 1 (1-2014)
Abstract

The Stone-column is a useful method for increasing the bearing capacity and reducing settlement of foundation soil. The prediction of accurate ultimate bearing capacity of stone columns is very important in soil improvement techniques. Bulging failure mechanism usually controls the failure mechanism. In this paper, an imaginary retaining wall is used such that it stretches vertically from the stone column edge. A simple analytical method is introduced for estimation of the ultimate bearing capacity of the stone column using Coulomb lateral earth pressure theory. Presented method needs conventional Mohr-coloumb shear strength parameters of the stone column material and the native soil for estimation the ultimate bearing capacity of stone column. The validity of the developed method has been verified using finite element method and test data. Parametric studies have been carried out and effects of contributing parameters such as stone column diameter, column spacing, and the internal friction angle of the stone column material on the ultimate bearing capacity have been investigated.
Jun Lin, Guojun Cai, Songyu Liu, Anand J. Puppala, Haifeng Zou,
Volume 15, Issue 3 (5-2017)
Abstract

The correlations and relationships between electrical resistivity and geotechnical parameters of soils have become very important for site investigation. However, there is a lack of understanding about the relationships between electrical resistivity and geotechnical parameter values. The resistivity piezocone penetration tests and laboratory tests have been conducted for geotechnical investigations of marine clay in Jiangsu province of China to establish quantitative relationships between electrical and geotechnical data. The geotechnical investigation reveals that electrical resistivity values are very low for marine clay in Jiangsu, ranging from 5 to 10 Ω m. The correlations between electrical resistivity and geotechnical parameters are examined using Spearman’s rank correlation test that is a rank-based test for correlation between two variables without any assumption about the data distribution. It was shown that the electrical resistivity has strong bonds with the moisture content, void ratio, salt content and plasticity index. In terms of quantitative relationships, good fitting relationships between electrical resistivity and selected geotechnical parameters are observed. The statistical analysis indicates that the electrical resistivity is a good indirect predictor of selected geotechnical parameters. The data studied demonstrates the usefulness of the in situ resistivity method in geotechnical investigations, which have an advantage over other geotechnical methods in cost performance.



Volume 15, Issue 6 (9-2017)
Abstract

Pile load tests and numerical analysis of a small-scale model pile in unsaturated clayey soil are presented in this paper. A small-scale model pile was simulated to bear a static axial loading in unsaturated soil using finite element method. All parameters used in the finite element method were obtained in laboratory tests, including the direct shear test, interface direct shear test, and filter paper method. The numerical analysis results were compared with the pile load test results. The results show that the general trend of pile load and pile head settlement relationship obtained by the numerical analysis shows a good consistence with the pile load test results. With increasing water content of the soil, the matric suction, dilatancy angle and shear strength decrease, and consequently the ultimate bearing capacity of pile decreases.



Page 1 from 1     

© 2019 All Rights Reserved | International Journal of Civil Engineering